Setting Items for IP-FAX Settings > LAN Settings

Item

Settings and Descriptions

Use LAN

Select whether to enable or disable sending and receiving IP faxes on the intranet.

Your Phone Number

Set the fax number you want to use when sending IP faxes to IP fax-compatible devices on the intranet (LAN). This appears as a header on outgoing faxes. You can enter up to 20 characters using 0-9 + or spaces.

Main Unit URI

Make the following settings according to the connection environment you will use.

  • When not using a SIP server:

    sip:<<User name>>@<<Host name or IP address of the printer>>

  • When using a SIP server:

    sip:<<SIP user name of the printer>>*@<<Host name or IP address of the SIP server>>

SIP RX Port Number

Enter the port number for receiving incoming SIP packets using single-byte numbers within a range of 1 to 65535.

SIP TX Transport

Select the protocol to be used when sending outgoing SIP requests from UDP or TCP.

*: The SIP user name is the name that is registered to the SIP server associated with the IP address. This SIP user name is used as the destination when receiving IP faxes. Set any number or name that does not overlap with other fax machines, such as an extension number.

SIP Server Settings

Item

Settings and Descriptions

Use SIP Server

Select whether or not to use a SIP server.

Primary Registrar Server

Server Address

Enter the host name or IP address for the primary registrar server. You can enter 0 to 127 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Port Number

Enter the port number for the primary registrar server using single-byte numbers within a range of 1 to 65535.

User Name

Enter a user name to access the primary registrar server. You can enter 0 to 32 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Password

Enter a password to access the primary registrar server. You can enter 0 to 32 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Secondary Registrar Server

Server Address

Enter the host name or IP address for the secondary registrar server. You can enter 0 to 127 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Port Number

Enter the port number for the secondary registrar server using single-byte numbers within a range of 1 to 65535.

User Name

Enter a user name to access the secondary registrar server. You can enter 0 to 32 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Password

Enter a password to access the secondary registrar server. You can enter 0 to 32 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Primary Proxy Server

Server Address

Enter the host name or IP address for the primary proxy server. You can enter 0 to 127 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Port Number

Enter the port number for the primary proxy server using single-byte numbers within a range of 1 to 65535.

User Name

Enter a user name to access the primary proxy server. You can enter 0 to 32 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Password

Enter a password to access the primary proxy server. You can enter 0 to 32 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Secondary Proxy Server

Server Address

Enter the host name or IP address for the secondary proxy server. You can enter 0 to 127 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Port Number

Enter the port number for the secondary proxy server using single-byte numbers within a range of 1 to 65535.

User Name

Enter a user name to access the secondary proxy server. You can enter 0 to 32 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Password

Enter a password to access the secondary proxy server. You can enter 0 to 32 characters that can be expressed in ASCII (0x20 to 0x7E). However, you cannot use whitespaces or the following characters: "<>\^`{¦}

Note:

A single SIP server can function as both a registrar server and a proxy server. In this case, enter the same setting values for the Server Address.

Media (T.38) Settings

Item

Settings and Descriptions

T.38 TX Transport

After establishing a SIP session, select the protocol to be used when sending and receiving data from UDPTL or TCP.

T.38 Media Type

After establishing a SIP session, select the type of media stream to be used when sending and receiving data from image or application.

T.38 RX Port Number

Enter the port number for receiving T.38 data using single-byte numbers within a range of 1 to 65535.

RTP RX Port Number

Enter the port number for receiving RTP (Real-time Transport Protocol) data using single-byte numbers within a range of 1024 to 65534.