forceStopSound


Forcibly sends the buzzer sound command.

The error status of this API is the result of sending data to the devices.

The processing result of the devices using this API is notified to the listener method set by the setReceiveEventListener API of the Printer class.

Syntax

 
public void forceStopSound(int timeout) throws Epos2Exception

Parameter

timeout

Specifies the timeout period before completion of command transmission in milliseconds.

Value

Description

0 to 600000

Timeout period (in milliseconds)

Printer.PARAM_DEFAULT

Specifies the default value (10000).

Exception

When the process fails, Epos2Exception with one of the following error status occurs.

Error status

Description

ERR_PARAM

An invalid parameter was passed.

ERR_MEMORY

Memory necessary for processing could not be allocated.

ERR_FAILURE

An unknown error occurred.

ERR_PROCESSING

Could not run the process.

ERR_ILLEGAL

This API was called while no communication had been started.

Supplementary explanation

  • The drawer and optional external buzzer cannot be connected simultaneously.
  • This API cannot be used if the printer is not equipped with a buzzer.
  • For TM-H6000V, the “Command execution during offline” setting must be enabled.
    Refer to TM-H6000V Utility User’s Manual for more information.
  • Available during ePOS-Device XML control.
 