Select your printer model

Parameters are refined by the selected printer.

interval


Specifies the interval to update the printer status.

Syntax

Setter

 
- (int) setInterval:(long) interval

Getter

 
- (long) getInterval

Value

Specifies the interval to update the printer status (in milliseconds). The default value is 3000.

Value

Description

Integer from 1000 to 600000

Interval to update the printer status (in milliseconds).

EPOS2_PARAM_DEFAULT

Specifies the default value (3000).

Return value

Error status

Description

EPOS2_SUCCESS

The function was executed successfully.

EPOS2_ERR_PARAM

An invalid parameter was passed.

Supplementary explanation

The new set value takes effect upon the next printer status notification.

 