DLE DC4   (fn=1)


[Name]

Generate pulse in real-time

[Format]

ASCII
   
DLE
  
DC4
  
fn
  
m
  
t
Hex
10
14
01
m
t
Decimal
16
20
1
m
t

[Range]

fn = 1
m = 0, 1
t = 1 – 8

[Description]

Outputs the pulse specified by t to connector pin m as follows in real time:
m
Connector pin
0
Drawer kick-out connector pin 2
[For optional internal buzzer specifications]
Drawer kick connector pin 2 or optional internal buzzer drive signal 1
1
Drawer kick-out connector pin 5
[For optional internal buzzer specifications]
Drawer kick connector pin 5 or optional internal buzzer drive signal 2
The pulse ON time is [t × 100 ms] and the OFF time is [t × 100 ms]

[Default]

None

[Notes]

  • This is a Real-time command. Refer to Notes of Real-time Commands for usage note.
  • This command is ignored in the following states:
    • In error status
    • When a pulse is being output to the drawer kick-out connector
    • During transmission of block data (Header – NUL)
    • When this command is disabled by GS ( D
  • It is not possible to output the pulses to the drawer kick-out connector pin 2 and 5 at the same time.
 