Select your printer model
Parameters are refined by the selected printer.
- EU-m30
- TM-J2000
- TM-J2100
- TM-L90
- TM-L90 LFC
- TM-L100
- TM-m10
- TM-m30
- TM-m30II
- TM-m30II-H
- TM-m30III
- TM-m30III-H
- TM-m30II-NT
- TM-m30II-S
- TM-m30II-SL
- TM-m50
- TM-m50II
- TM-m50II-H
- TM-P20
- TM-P20II
- TM-P60
- TM-P60II
- TM-P80
- TM-P80II
- TM-T20
- TM-T20II
- TM-T20III
- TM-T20IIIL
- TM-T20IV-L
- TM-T20X
- TM-T20X-II
- TM-T70
- TM-T70II
- TM-T81III
- TM-T82II
- TM-T82III
- TM-T82IIIL
- TM-T82IV-L
- TM-T82X
- TM-T82X-II
- TM-T83III
- TM-T83IV
- TM-T88IV
- TM-T88V
- TM-T88VI
- TM-T88VII
- TM-T90
- TM-T100
- TM-U220
- TM-U220II
- TM-U230
GS ( k <Function 380>
[Name]
2-dimensional GS1 DataBar: Store the data in the symbol storage area
[Format]
ASCII
|
|
GS
|
|
(
|
|
k
|
|
pL
|
|
pH
|
|
cn
|
|
fn
|
|
m
|
|
n
|
|
d1...dk
|
Hex
|
1D
|
28
|
6B
|
pL
|
pH
|
33
|
50
|
30
|
n
|
d1...dk
|
||||||||||
Decimal
|
29
|
40
|
107
|
pL
|
pH
|
51
|
80
|
48
|
n
|
d1...dk
|
[Range]
(pL + pH × 256) = 6 – 259
cn = 51
fn = 80
m = 48
n = 72, 73, 76
k = (pL + pH × 256) - 4
d: different depending on the type of 2-dimensional GS1 DataBar. Refer to the table
in [Description].
[Description]
The 2-dimensional GS1 DataBar symbol data (d1...dk) specified by n is saved in the symbol storage area.
n
|
2-dimensional GS1 DataBar
|
Symbol data (SP indicates a space)
|
||
---|---|---|---|---|
Data (k)
|
Characters (ASCII)
|
Data (d)
|
||
72
|
GS1 DataBar Stacked
|
k = 13
|
"0" – "9"
|
d = 48 – 57
|
73
|
GS1 DataBar Stacked Omnidirectional
|
k = 13
|
"0" – "9"
|
d = 48 – 57 [However d1 = 48, 49]
|
76
|
GS1 DataBar Expanded Stacked
|
k = 0 – 255
|
0 – 9, A – D, a – d, SP, !, ", %, $, ', (, ), *, +, ,, -, ., /, :, ;, <, =, >, ?,
_, {
|
d = 48 – 57, 65 – 90, 97 – 122,
d = 32 – 34, 37 – 47, 58 – 63, 95,123
[However d1 = 40, d2 = 48 – 57, 48 ≤d3 ≤ 57,
d1 = 48 – 57, d2 = 48 – 57]
|
[Notes]
-
Data stored in the symbol storage area by this function is processed by GS ( k <Function 381> and GS ( k <Function 382> . The data in the symbol storage area are reserved after processing GS ( k <Function 381> or GS ( k <Function 382> .
-
k bytes of d1...dk are processed as symbol data.
-
Settings of this function are effective until the following processing is performed:
-
-
GS ( k <Function 080> or GS ( k <Function 180> or GS ( k <Function 280> or GS ( k <Function 380> or GS ( k <Function 480> is executed
-
ESC @ is executed
-
The printer is reset or the power is turned off
-
-
Refer to GS ( k for printing the GS1 DataBar shown below.
-
GS1 DataBar Omnidirectional, GS1 DataBar Truncated, GS1 DataBar Limited, GS1 DataBar Expanded
[Description: Applied to GS1 DataBar Stacked and GS1 DataBar Stacked Omnidirectional]
-
Transmit the 13-digit product identification number, excluding the application identifier (AI) and check digit, from the host.
[Description: Applied to GS1 DataBar Stacked]
-
Transmit the 2-byte data shown in the following table ([Hex = 7Bh / Decimal = 123] + character code) from the host for the special character (FNC1) and symbol data "(", ")". ("+" in the table is not included in the transmission data).
-
DataTransmission data from hostASCIIHexDecimalFNC1{ + 17B + 31123 + 49({ + (7B + 28123 + 40){ + )7B + 29123 + 41
Quick Access
- [Name]
- [Format]
- [Range]
- [Description]
- [Notes]
ESC/POS® includes patented or patent pending commands. The contents must not be disclosed
to third parties.
- Introduction
- Command Lists
- Commands in Code Order
- Applicable printers
- Command List by Model
- EU-m30
- TM-J2000, TM-J2100
- TM-L90
- TM-L90 LFC
- TM-L100
- TM-m10
- TM-m30
- TM-m30II
- TM-m30II-H
- TM-m30II-NT
- TM-m30II-S
- TM-m30II-SL
- TM-m30III
- TM-m30III-H
- TM-m50
- TM-m50II
- TM-m50II-H
- TM-P20
- TM-P20II
- TM-P60
- TM-P60II
- TM-P80
- TM-P80II
- TM-T100
- TM-T20
- TM-T20II
- TM-T20III
- TM-T20IIIL
- TM-T20IV-L
- TM-T20X
- TM-T20X-II
- TM-T70
- TM-T70II
- TM-T81III
- TM-T82II
- TM-T82III
- TM-T82IIIL
- TM-T82IV-L
- TM-T82X
- TM-T82X-II
- TM-T83III
- TM-T83IV
- TM-T88IV
- TM-T88V
- TM-T88VI
- TM-T88VII
- TM-T90
- TM-U220
- TM-U220II
- TM-U230
- Obsolete Commands
- Commands Arranged by Function
- Print Commands
- Line Spacing Commands
- Character Commands
- Printing Paper Commands
- Label and black mark control
- Print Position Commands
- Paper Sensor Commands
- Mechanism Control Commands
- Bit Image Commands
- Bit Image
- GS ( L / GS 8 L
- GS D
- Graphics
- NV Graphics
- Download Graphics
- Panel Button Commands
- Status Commands
- Barcode Commands
- Two-dimensional Code Commands
- GS ( k
- PDF417
- QR Code
- MaxiCode
- 2-dimensional GS1 DataBar
- Composite Symbology
- Aztec Code
- DataMatrix
- Macro Function Commands
- Kanji Commands
- Miscellaneous Commands
- DLE ENQ
- DLE DC4 <fn=1>
- DLE DC4 <fn=2>
- DLE DC4 <fn=3>
- DLE DC4 <fn=7>
- DLE DC4 <fn=8>
- ESC ( Y
- ESC =
- ESC @
- ESC L
- ESC S
- ESC p
- GS ( A
- GS ( D
- GS I
- GS P
- GS g 0
- GS g 2
- GS z 0
- Response or status transmission
- Print control methods
- Beeper tone control
- Graphics drawing
- Receipt enhancement control
- Page mode control
- Customize Commands
- User setup
- GS ( E
- GS ( E <fn=1>
- GS ( E <fn=2>
- GS ( E <fn=3>
- GS ( E <fn=4>
- GS ( E <fn=5>
- GS ( E <fn=6>
- GS ( E <fn=7>
- GS ( E <fn=8>
- GS ( E <fn=9>
- GS ( E <fn=10>
- GS ( E <fn=11>
- GS ( E <fn=12>
- GS ( E <fn=13>
- GS ( E <fn=14>
- GS ( E <fn=15>
- GS ( E <fn=16>
- GS ( E <fn=48>
- GS ( E <fn=49>
- GS ( E <fn=50>
- GS ( E <fn=51>
- GS ( E <fn=52>
- GS ( E <fn=99>
- GS ( E <fn=100>
- Printer customization
- NV user memory
- User setup
- Counter Printing Commands
- Programming Examples
- Appendixes