Select your printer model

Parameters are refined by the selected printer.
  • EU-m30
  • TM-J2000
  • TM-J2100
  • TM-L90
  • TM-L90 LFC
  • TM-L100
  • TM-m10
  • TM-m30
  • TM-m30II
  • TM-m30II-H
  • TM-m30III
  • TM-m30III-H
  • TM-m30II-NT
  • TM-m30II-S
  • TM-m30II-SL
  • TM-m50
  • TM-m50II
  • TM-m50II-H
  • TM-P20
  • TM-P20II
  • TM-P60
  • TM-P60II
  • TM-P80
  • TM-P80II
  • TM-T20
  • TM-T20II
  • TM-T20III
  • TM-T20IIIL
  • TM-T20IV-L
  • TM-T20X
  • TM-T20X-II
  • TM-T70
  • TM-T70II
  • TM-T81III
  • TM-T82II
  • TM-T82III
  • TM-T82IIIL
  • TM-T82IV-L
  • TM-T82X
  • TM-T82X-II
  • TM-T83III
  • TM-T83IV
  • TM-T88IV
  • TM-T88V
  • TM-T88VI
  • TM-T88VII
  • TM-T90
  • TM-T100
  • TM-U220
  • TM-U220II
  • TM-U230

GS ( k   <Function 380>


[Name]

2-dimensional GS1 DataBar: Store the data in the symbol storage area

[Format]

ASCII
   
GS
  
(
  
k
  
pL
  
pH
  
cn
  
fn
  
m
  
n
  
d1...dk
Hex
1D
28
6B
pL
pH
33
50
30
n
d1...dk
Decimal
29
40
107
pL
pH
51
80
48
n
d1...dk

[Range]

(pL + pH × 256) = 6 – 259
cn = 51
fn = 80
m = 48
n = 72, 73, 76
k = (pL + pH × 256) - 4
d: different depending on the type of 2-dimensional GS1 DataBar. Refer to the table in [Description].

[Description]

The 2-dimensional GS1 DataBar symbol data (d1...dk) specified by n is saved in the symbol storage area.
n
2-dimensional GS1 DataBar
Symbol data (SP indicates a space)
Data (k)
Characters (ASCII)
Data (d)
72
GS1 DataBar Stacked
k = 13
"0" – "9"
d = 48 – 57
73
GS1 DataBar Stacked Omnidirectional
k = 13
"0" – "9"
d = 48 – 57 [However d1 = 48, 49]
76
GS1 DataBar Expanded Stacked
k = 0 – 255
0 – 9, A – D, a – d, SP, !, ", %, $, ', (, ), *, +, ,, -, ., /, :, ;, <, =, >, ?, _, {
d = 48 – 57, 65 – 90, 97 – 122,
d = 32 – 34, 37 – 47, 58 – 63, 95,123
[However d1 = 40, d2 = 48 – 57, 48 ≤d3 ≤ 57,
d1 = 48 – 57, d2 = 48 – 57]

[Notes]

[Description: Applied to GS1 DataBar Stacked and GS1 DataBar Stacked Omnidirectional]

  • Transmit the 13-digit product identification number, excluding the application identifier (AI) and check digit, from the host.

[Description: Applied to GS1 DataBar Stacked]

  • Transmit the 2-byte data shown in the following table ([Hex = 7Bh / Decimal = 123] + character code) from the host for the special character (FNC1) and symbol data "(", ")". ("+" in the table is not included in the transmission data).
  • Data
    Transmission data from host
    ASCII
    Hex
    Decimal
    FNC1
    { + 1
    7B + 31
    123 + 49
    (
    { + (
    7B + 28
    123 + 40
    )
    { + )
    7B + 29
    123 + 41
 

Quick Access

  • [Name]
  • [Format]
  • [Range]
  • [Description]
  • [Notes]

ESC/POS® includes patented or patent pending commands. The contents must not be disclosed to third parties.


ESC/POS® Command Reference for TM Printers

Jump to the top